Una nova vía per a gestionar instal·lacions domòtiques i d'edificis intel·ligents

  • cabecera
  • cabecera
  • cabecera
  • cabecera
  • cabecera
  • cabecera

Domorela's Blog: Security by Design: Decision-making

In the previous article we talked about security considerations giving examples of two security measures taken in the design of Domorela. We want to remark in this article that from the very beginning we have taken security into account. That is, we started the decision-making process with security in mind and we think it would be applied on the design of every project in which Domorela is present.

Llegeix més...

Domorela's Blog: Security by Design: Secure components

Domorela allows to reduce the attack surface, because is a security hardened platform and allows for a series of mechanics to design and deploy projects using security measures in order to improve IT security. For example, among other security measures taken during its design, its hardware includes security components dedicated to AAA security and its embedded software is a custom toolset to avoid attacks conceived for well known embedded operation system distributions.

Llegeix més...

Domorela's Blog: ETS6 and Modbus compatibility

We resume the publications in our Blog announcing that we have just finished the implementation of Modbus integration within Domorela software, also that Domorela platform is now able to import ETS6 projects.

On past July, ETS6 beta was opened to any people interested on its testing, so we asked for access to the beta release. A few weeks later we finished the project conversion tests with ETS6 (ETS4 -> ETS6 and ETS5 -> ETS6), that we can say works very well, jointly with the new code for importing them from ETS6 into Domorela configuration, and went to vacations with job done.

Llegeix més...

Domorela's Blog: Modbus compatibility

As many people are asking us about Modbus compatibility, we want to announce that we are currently testing the new software code for the Modbus Module which will be included in the next version of Domorela's application software: 1.1.0.

The new Modbus Module will be inactive by default, being started only in the case an Admin Level user sets the module as an active module in order to manage Modbus Points present in the installation.

Llegeix més...

Domorela's Blog: Modbus integration in Domorela (I)

In our previous article we announced the new Modbus module will be included in the 1.1.0 release version of Domorela software and how to activate it. In this article we'll talk about the seamlessly integration between KNX and Modbus elements in the Domorela platform.

Llegeix més...

Domorela's Blog: Modbus integration in Domorela (II)

In the past article we explained how Modbus elements, Datapoints and Slaves, can be configured in Domorela jointly with the KNX elements: Addresses, Datapoints and Devices.

In this article we explain how the users can visualize Modbus elements in the different Views of Domorela's WUI.

Llegeix més...

Domorela's Blog: Modbus integration in Domorela (III)

Going to the Panel and Graph Views, Modbus Points are selectable to be added as widgets to Panels and as data series to Graphs, in the latter case after being configured as History values in the same way as with KNX Addresses.

Llegeix més...

Domorela's Blog: Modbus hardware interface

Modbus hardware interface is defined by the RS-485 standard, which determines two ways to interconnect Modbus devices: bus circuits using 4-Wire for Full Duplex communications or 2-Wire for Half Duplex communications.

Llegeix més...

Blog Articles